| Immunity
Experienced Staff Understands Testing, Trouble-shooting & Mitigation
EMC Integrity, Inc. is a full-compliance immunity test lab, certified annually to ISO 17025: 2005, which is the ISO standard for test and measurement laboratories. Our facility boasts cutting-edge capabilities and a knowledgeable staff ready to assist you with all your testing needs. Contact us today to learn more about our experience and services.
| COMMERCIAL IMMUNITY TEST LAB CAPABILITIES |
| Test Area | Test | Standard | Maximum Level |
| Ground Plane 1 or 2 |
Electrostatic discharge
(ESD) |
IEC/EN/KN
61000-4-2 |
+/- 15 kV Air
+/- 8 kV Contact |
| Completely Anechoic - lined Chamber (CALC) |
Radiated RF Immunity |
IEC/EN/KN
61000-4-3 |
>20 V/m (with modulation.)
10 kHz to 40 GHz |
| Ground Plane 1 or 2 |
Electrical Fast
Transient/Burst |
IEC/EN/KN
61000-4-4 |
+/- 4.4 kV â?? AC (Single or
Multi-phase) & I/O |
| Ground Plane 1 or 2 |
Surge Immunity |
IEC/EN/KN
61000-4-5 |
+/- 6.6 kV â?? AC (Single or
Multi-phase) & I/O |
| Ground Plane 1 or 2 |
Conducted RF
Immunity |
IEC/EN/KN
61000-4-6 |
20 Vrms
10 kHz to 80 MHz |
| Ground Plane 1 or 2 |
Power Frequency
Magnetic Field Immunity |
IEC/EN/KN
61000-4-8 |
30 A/m - Immersion Method
600 A/m - Proximity Method |
| Ground Plane 1 or 2 |
Voltage Sags, Dips and
Interruptions |
IEC/EN/KN
61000-4-11 |
Completely programmable; able to support all standard and custom requirements â?? single or multi-phase |
| 10-METER EMISSIONS TEST LAB SPECIFICATIONS |
| Parameter | Capability |
| Accreditation |
NVLAP & NEMKO accredited to ISO 17025: 2005; individual Eastern
Rim country accreditations include Korea |
| Calibration |
Critical test equipment calibrated annually |
| Verification |
Test equipment verification performed before every formal test |
| EUT Power |
120 Vac/60 Hz/1-Ф @ 30 Amps (Facility)
208 Vac/60 Hz/3-Ф @ 30 Amps/phase (Facility)
230 Vac/1-Ф 30 A/Ф (Generator)
100-277 Vac/1-Ф 40-20 A (Programmable AC Power Source) |
| CALC Access |
Door: 7' tall x 4' wide |
| EUT Monitoring |
Support equipment located adjacent test area |
| EUT-SE Interface |
EMCI recommends a minimum of 12 feet of I/O cabling between the
equipment under test and support equipment |
EMCI Trouble-Shooting
and Mitigation Process
In the event of failure during testing, EMCI provides expert troubleshooting & mitigation.
1. First, we determine the point of entry and devise a plan of action.
2. Next, we use our expertise to determine which circuitry is affected.
3. Then, we identify the coupling mechanism and implement the most effective mitigation techniques.
4. Finally, we assist the client in finding a cost-effective and manufacturable solution that meets their immediate and evolving needs.
|