Facilities
Commercial
OverviewImmunityEmissionsChamber vs. OATS
 

Immunity

Experienced Staff Understands Testing, Trouble-shooting & Mitigation

EMC Integrity, Inc. is a full-compliance immunity test lab, certified annually to ISO 17025: 2005, which is the ISO standard for test and measurement laboratories. Our facility boasts cutting-edge capabilities and a knowledgeable staff ready to assist you with all your testing needs. Contact us today to learn more about our experience and services.

COMMERCIAL IMMUNITY TEST LAB CAPABILITIES
Test AreaTestStandardMaximum Level
Ground Plane 1 or 2 Electrostatic discharge (ESD) IEC/EN/KN
61000-4-2
+/- 15 kV Air
+/- 8 kV Contact
Completely Anechoic - lined Chamber (CALC) Radiated RF Immunity IEC/EN/KN
61000-4-3
>20 V/m (with modulation.) 10 kHz to 40 GHz
Ground Plane 1 or 2 Electrical Fast Transient/Burst IEC/EN/KN
61000-4-4
+/- 4.4 kV â?? AC (Single or Multi-phase) & I/O
Ground Plane 1 or 2 Surge Immunity IEC/EN/KN
61000-4-5
+/- 6.6 kV â?? AC (Single or Multi-phase) & I/O
Ground Plane 1 or 2 Conducted RF Immunity IEC/EN/KN
61000-4-6
20 Vrms
10 kHz to 80 MHz
Ground Plane 1 or 2 Power Frequency Magnetic Field Immunity IEC/EN/KN
61000-4-8
30 A/m - Immersion Method
600 A/m - Proximity Method
Ground Plane 1 or 2 Voltage Sags, Dips and Interruptions IEC/EN/KN
61000-4-11
Completely programmable; able to support all standard and custom requirements â?? single or multi-phase
10-METER EMISSIONS TEST LAB SPECIFICATIONS
ParameterCapability
Accreditation NVLAP & NEMKO accredited to ISO 17025: 2005; individual Eastern Rim country accreditations include Korea
Calibration Critical test equipment calibrated annually
Verification Test equipment verification performed before every formal test
EUT Power 120 Vac/60 Hz/1-Ф @ 30 Amps (Facility)
208 Vac/60 Hz/3-Ф @ 30 Amps/phase (Facility)
230 Vac/1-Ф 30 A/Ф (Generator)
100-277 Vac/1-Ф 40-20 A (Programmable AC Power Source)
CALC Access Door: 7' tall x 4' wide
EUT Monitoring Support equipment located adjacent test area
EUT-SE Interface EMCI recommends a minimum of 12 feet of I/O cabling between the equipment under test and support equipment

EMCI Trouble-Shooting and Mitigation Process

In the event of failure during testing, EMCI provides expert troubleshooting & mitigation.

1. First, we determine the point of entry and devise a plan of action.

2. Next, we use our expertise to determine which circuitry is affected.

3. Then, we identify the coupling mechanism and implement the most effective mitigation techniques.

4. Finally, we assist the client in finding a cost-effective and manufacturable solution that meets their immediate and evolving needs.

tel: 888.423.6275 | 303.776.7249  